 BTE5000 / PTE5000 / PTU5000 Series
Precision differential pressure transmitters
FEATURES * 25 mbar to 10 bar or 0.3 to 150 psi differential pressure * High level output , 1...6 V or 4...20 mA (2-wire connection)12 * Precision temperature compensated and calibrated * Rugged aluminium housing * Female 1/8" BSP and 1/8" NPT fittings
MEDIA COMPATIBILITY
Pressure inlet: Non-corrosive, non-ionic working fluids such as air, dry gases and the like Housing: Aluminium, protection class IP 67 (according to DIN EN 60529) respectively NEMA 61
ELECTRICAL CONNECTION SPECIFICATIONS10,11
Maximum ratings Supply voltage Output current BTE(M)/PTE/PTU5...D1... Source Sink Output current BTE(M)/PTE/PTU5...D4... Temperature limits Storage Operating Compensated 12...32 V
Sensor
1...6 V output version
+Vs Vout -Vs case 1 2 4 3 GND
V
12 to 32 V
20 mA 10 mA 30 mA -55 to 100C -40 to 85C 0 to 70C
4...20 mA output version
+Vs 1 Sensor -Vs 4 12 to 32 V
Proof pressure2 BTEM5x025... / PTx5000.3... 0.35 bar / 5 psi BTEM5x070..., BTEM5x350... / 1.4 bar / 20 psi PTx5001..., PTx5005... all others 2 x rated pressure Pressure at any port3 12 bar / 175 psi
V
RL
GND
case 3
June 2008 / 101
1/6
www.sensortechnics.com
BTE5000 / PTE5000 / PTU5000 Series
Precision differential pressure transmitters
COMMON PERFORMANCE CHARACTERISTICS8
Characteristics
Operating pressure BTEM50025... BTEM5P025... BTEM50070... BTEM5P070... BTEM50350... BTEM5P350... BTE5001... BTE5P01... BTE5002... BTE5005... BTE5010... PTU5000.3... PTx5001... PTx5P01... PTx5005... PTx5P05... PTx5015... PTx5P15... PTx5030... PTx5100... PTx5150... Thermal effects (0 to 70C)6 Offset all 70 mbar / 1 psid devices all 350 mbar / 5 psid devices all others
Min.
0 -25 0 -70 0 -350 0 -1 0 0 0 0 0 -1 0 -5 0 -15 0 0 0
Typ.
Max.
25 25 70 70 350 350 1 1 2 5 10 0.3 1 1 5 5 15 15 30 100 150
Unit
mbar
bar
p si d
Span Non-linearity and hysteresis4 Long term stability5 Output noise (0 f 1 kHz) Response time (10 to 90 %)
0.025 0.008 0.005 0.001 0.2 0.2 0.04 1
0.125 0.040 0.025 0.045 1
%FSO/C
%FSO
ms
June 2008 / 101
2/6
www.sensortechnics.com
BTE5000 / PTE5000 / PTU5000 Series
Precision differential pressure transmitters
PERFORMANCE CHARACTERISTICS8
1...6 V output versions (unless otherwise noted VS = 15 V, tamb = 25C, RL > 100 k, com. mode pressure = 0)
Characteristics
Zero pressure offset Full scale span7 Full scale output Power supply rejection Output impedance Power consumption Offset Span BTE(M)5P... / PTx5P... all others BTE(M)5P... / PTx5P... all others
Min.
3.4 0.9 2.4 4.9
Typ.
3.5 1.0 2.5 5.0 6.0 0.05 0.03
Max.
3.6 1.1 2.6 5.1
Unit
V
%FSO/V 50 mW
60
4...20 mA output versions (unless otherwise noted VS = 15 V, tamb = 25C, RL = 100 , com. mode pressure = 0)
Characteristics
Zero pressure offset Full scale span7 Full scale output Power supply rejection Output impedance Power consumption (IL = 20 mA) Offset Span BTE(M)5P... / PTx5P... all others BTE(M)5P... / PTx5P... all others
Min.
11.9 3.9 7.9 15.9
Typ.
12.0 4.0 8.0 16.0 20.0 0.05 0.03
Max.
12.1 4.1 8.1 16.1
Unit
mA
%FSO/V 0.1 mW
260
Specification notes:
1. IP 67 protection for BTE(M)5...A / PTx5...A is given with locked connector only. 2. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element. 3. This is the highest pressure which can be applied to any port at any time. At the same time the differential pressure between the ports H and L must not exceed the maximum proof pressure. 4. Non-linearity refers to the Best Straight Line fit measured for offset, full scale span and 1/2 full scale span. 5. Long term stability is the change in output after one year or 1 million pressure cycles. 6. Thermal effects tested and guaranteed from 0 - 70 C relative to 25. All specifications shown are relative to 25C. 7. Full scale span is the algebraic difference between the positive full scale output and zero pressure offset. 8. Higher pressure applied to port H. 9. Test are in accordance with EN61000-6-2, April 1999. 10. CE-labelling is in accordance with 89/336/EEC. 11. The pressure transmitters must not be used as safety accessories according to article 1, 2.1.3 of the directive 97/23/EC. 12. 0...10 V square rooting output signal on special request.
June 2008 / 101
3/6
www.sensortechnics.com
BTE5000 / PTE5000 / PTU5000 Series
Precision differential pressure transmitters
ELECTROMAGNETIC CAPABILITY9
Test conditions
Radiated, radio frequency electromagnetic field immunity (RFI) Electrical fast transient / burst immunity (EFT) Electrostatic discharge immunity test (ESD) Immunity to conducted disturbances induced by radio-frequency fields EN61000-4-3: Grade 3 10 V/m, 80 MHz to 1000 MHz 80 % AMC (1 kHz) Grade 3 2 kV Grade 4 8 kV, contact discharge Grade 3 0,15 to 80 MHz 10 V, 80 % AMC (1 kHz)
Criterion
A B B A
Interference
<1 % FSO <1 % FSO <1 % FSO <1 % FSO
EN61000-4-4: EN61000-4-2: EN61000-4-6:
LOAD LIMITATION
4...20 mA output versions
1200 Ohm 1000 800 600 400 200
operating range
0
10
20
30 V Vsupply
RECOMMENDED CABLE/CONNECTOR ACCESSORY
for connector version
Order number ZK000101, other cable length on special request
NOM 2 m
PIN CONNECTION
36.5
NOM 60
Pin 1 2 3 4
Flying lead end brown green white + shield yellow
M12 x 1 O 20
Included in delivery!
June 2008 / 101
4/6
www.sensortechnics.com
BTE5000 / PTE5000 / PTU5000 Series
Precision differential pressure transmitters
OUTLINE DRAWING
Connector version
40.0 (1.58) 20.0 (0.79) NOM 86.0 (3.39) 72.0 (2.84) 13.5 diam. (0.53) H: high pressure port L: low pressure port mating plug 8.0 (0.31) min. M12 x 1 (0.47) 8.0 (0.31) min. 2 x M5 (UNC 10-24)
mass: typ. 170 g Pin 1 2 3 4
4 1 2 3
9.0 (0.35)
BTE.../PTE...: 2 x 1/8" BSP PTU...: 2 x 1/8" NPT
ELECTRICAL CONNECTION Connection 1-6V 4 - 20 mA output output +Vs +Vs Vout NC case case -Vs -Vs dimensions in mm (inches)
Cable version
40.0 (1.58) 20.0 (0.79)
90.0 (3.54) 72.0 (2.84) 13.5 diam. (0.53)
H: high pressure port L: low pressure port
8.0 (0.31) min.
1 m (3.3 ft) shielded cable 4 x 0.25 mm (AWG24)
8.0 (0.31) min. 2 x M5 (UNC 10-24) 9.0 (0.35)
BTE.../PTE...: 2 x 1/8" BSP PTU...: 2 x 1/8" NPT
ELECTRICAL CONNECTION Connection 4 - 20 mA 1-6V output output case/shield case/shield +Vs +Vs NC NC Vout NC -Vs -Vs dimensions in mm (inches)
mass: typ. 220 g bare brown white green yellow
June 2008 / 101
5/6
www.sensortechnics.com
BTE5000 / PTE5000 / PTU5000 Series
Precision differential pressure transmitters
ORDERING INFORMATION
Order number Operating pressure
0 to 25 mbar 0 to 25 mbar 0 to 70 mbar 0 to 70 mbar 0 to 350 mbar 0 to 350 mbar 0 to 1 bar 0 to 1 bar 0 to 2 bar 0 to 5 bar 0 to 10 bar 0 to 0.3 psi 0 to 1 psi 0 to 1 psi 0 to 5 psi 0 to 5 psi 0 to 15 psi 0 to 15 psi 0 to 30 psi 0 to 100 psi 0 to 150 psi 0 to 0.3 psi 0 to 1 psi 0 to 1 psi 0 to 5 psi 0 to 5 psi 0 to 15 psi 0 to 15 psi 0 to 30 psi 0 to 100 psi 0 to 150 psi
Fitting
1...6 V output Connector version BTEM50025D1A BTEM5P025D1A BTEM50070D1A BTEM5P070D1A BTEM50350D1A BTEM5P350D1A BTE5001D1A BTE5P01D1A BTE5002D1A BTE5005D1A BTE5010D1A PTE5000.3D1A PTE5001D1A PTE5P01D1A PTE5005D1A PTE5P05D1A PTE5015D1A PTE5P15D1A PTE5030D1A PTE5100D1A PTE5150D1A PTU5000.3D1A PTU5001D1A PTU5P01D1A PTU5005D1A PTU5P05D1A PTU5015D1A PTU5P15D1A PTU5030D1A PTU5100D1A PTU5150D1A Cable version BTEM50025D1C BTEM5P025D1C BTEM50070D1C BTEM5P070D1C BTEM50350D1C BTEM5P350D1C BTE5001D1C BTE5P01D1C BTE5002D1C BTE5005D1C BTE5010D1C PTE5000.3D1C PTE5001D1C PTE5P01D1C PTE5005D1C PTE5P05D1C PTE5015D1C PTE5P15D1C PTE5030D1C PTE5100D1C PTE5150D1C PTU5000.3D1C PTU5001D1C PTU5P01D1C PTU5005D1C PTU5P05D1C PTU5015D1C PTU5P15D1C PTU5030D1C PTU5100D1C PTU5150D1C
4...20 mA output Connector version BTEM50025D4A BTEM5P025D4A BTEM50070D4A BTEM5P070D4A BTEM50350D4A BTEM5P350D4A BTE5001D4A BTE5P01D4A BTE5002D4A BTE5005D4A BTE5010D4A PTE5000.3D4A PTE5001D4A PTE5P01D4A PTE5005D4A PTE5P05D4A PTE5015D4A PTE5P15D4A PTE5030D4A PTE5100D4A PTE5150D4A PTU5000.3D4A PTU5001D4A PTU5P01D4A PTU5005D4A PTU5P05D4A PTU5015D4A PTU5P15D4A PTU5030D4A PTU5100D4A PTU5150D4A Cable version BTEM50025D4C BTEM5P025D4C BTEM50070D4C BTEM5P070D4C BTEM50350D4C BTEM5P350D4C BTE5001D4C BTE5P01D4C BTE5002D4C BTE5005D4C BTE5010D4C PTE5000.3D4C PTE5001D4C PTE5P01D4C PTE5005D4C PTE5P05D4C PTE5015D4C PTE5P15D4C PTE5030D4C PTE5100D4C PTE5150D4C PTU5000.3D4C PTU5001D4C PTU5P01D4C PTU5005D4C PTU5P05D4C PTU5015D4C PTU5P15D4C PTU5030D4C PTU5100D4C PTU5150D4C
1/8" BSP
1/8" NPT
Note:
Other pressure ranges and options are widely available. Please contact your nearest Sensortechnics sales representative.
Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others. June 2008 / 101 6/6
www.sensortechnics.com


▲Up To Search▲   

 
Price & Availability of PTU50003D1A

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X